Key Product Specifications:
- Chemical Name: 1,4-Dichlorobenzyl
- CAS Number: 623-25-6
- Molecular Formula: C7H6Cl2
- Appearance: White crystalline powder
- Purity: ≥99.5%
- Melting Point: 52-56°C
- Boiling Point: 245-247°C
- Flash Point: 113°C
- Solubility: Soluble in organic solvents, insoluble in water
| Parameter | Specification | Test Method |
|---|---|---|
| Assay (GC) | ≥99.5% | ASTM E260 |
| Water Content | ≤0.2% | Karl Fischer |
| Residue on Ignition | ≤0.1% | USP 281 |
| Heavy Metals (as Pb) | ≤10 ppm | USP 231 |
| Chlorinated Impurities | ≤0.5% | HPLC |
p-Dichlorobenzyl FAQ
Q: What are the primary industrial applications of p-Dichlorobenzyl?
A: p-Dichlorobenzyl serves as a crucial intermediate in numerous industrial processes. The pharmaceutical industry uses it in synthesizing active pharmaceutical ingredients (APIs), particularly for antimicrobial and antifungal agents. In agrochemical production, it's valuable for creating pesticides and herbicides. Additionally, it finds applications in dye manufacturing, polymer synthesis, and as a precursor for specialty chemicals. The compound's two reactive chlorine atoms make it particularly versatile for further chemical modifications.
Q: What safety precautions should be taken when handling p-Dichlorobenzyl?
A: Proper handling of p-Dichlorobenzyl requires strict safety measures due to its potential health effects. Always work in a well-ventilated area or fume hood, and wear appropriate personal protective equipment (PPE) including chemical-resistant gloves, safety goggles, and protective clothing. Avoid inhalation of dust or vapors - use respiratory protection if adequate ventilation isn't available. The compound may cause skin and eye irritation, and chronic exposure could affect the liver and kidneys. Store in a cool, dry place away from incompatible materials such as strong oxidizers and bases. In case of contact, flush affected areas with plenty of water and seek medical attention if irritation persists.
Q: How should p-Dichlorobenzyl be stored for long-term stability?
A: For optimal storage conditions, keep p-Dichlorobenzyl in its original tightly sealed container in a cool, dry place at temperatures below 30°C. Protect from direct sunlight and moisture by storing in amber glass bottles or properly lined metal containers. The storage area should be well-ventilated and separate from foodstuffs. Under these conditions, the product typically maintains stability for at least 24 months from the date of manufacture. For bulk quantities, nitrogen blanket storage is recommended to prevent oxidation. Always check for discoloration or unusual odor before use, as these may indicate degradation.
Packaging Options Available
We offer p-Dichlorobenzyl in various packaging configurations to meet different industrial needs:
- Lab Scale: 100g, 500g, 1kg in glass bottles
- Pilot Scale: 5kg, 10kg, 25kg in HDPE drums
- Industrial Scale: 50kg, 100kg, 200kg in steel drums
- Custom Packaging: Available upon request for bulk orders
Global Shipping and Compliance
Our p-Dichlorobenzyl complies with international chemical regulations:
| REACH Compliance | Fully registered with appropriate testing data |
| Transport Classification | UN 3077, Class 9, Packing Group III |
| GHS Labeling | Signal Word: Warning; H302, H315, H319, H335 |
| SDS Availability | Available in multiple languages upon request |
| Customs Documentation | Complete commercial invoices, certificates of analysis, and material safety data sheets provided |
More p-Dichlorobenzyl FAQs
Q: What analytical methods are used for quality control of p-Dichlorobenzyl?
A: Our quality control process employs multiple analytical techniques to ensure product consistency. Gas chromatography (GC) with flame ionization detection is used for purity determination (typically ≥99.5%). HPLC analysis monitors for specific impurities. Melting point is verified by differential scanning calorimetry (DSC). Karl Fischer titration measures moisture content, while atomic absorption spectroscopy (AAS) tests for heavy metal contamination. Each batch is accompanied by a comprehensive Certificate of Analysis (CoA) detailing these test results.
Q: Can p-Dichlorobenzyl be customized for specific industrial applications?
A: Yes, we offer customization options for p-Dichlorobenzyl to meet specialized requirements. These include: particle size modification (micronized forms available), higher purity grades (up to 99.9% for pharmaceutical applications), stabilized formulations with antioxidants, and customized packaging with inert atmospheres. We can also provide technical support for process optimization involving p-Dichlorobenzyl. Many manufacturers require specific impurity profiles - we can adjust our purification processes to meet these needs while maintaining competitive pricing.
Q: What is the typical lead time for p-Dichlorobenzyl orders?
A: Standard lead times vary by order size and destination. For stock items, we typically ship within: 1-3 business days for laboratory quantities (<25kg), 3-5 business days for pilot-scale quantities (25-100kg), and 7-10 business days for full container loads. Customized products may require 2-4 weeks for production and quality control. We maintain strategic inventory positions globally to ensure reliable supply. Expedited shipping options are available for urgent requirements, and our logistics team can handle all necessary export documentation and hazardous materials declarations.
Technical Support and Additional Services
Beyond supplying high-quality p-Dichlorobenzyl, we provide comprehensive technical support:
- Process development assistance for new applications
- Troubleshooting for manufacturing challenges
- Regulatory compliance guidance for global markets
- Custom synthesis of derivatives and related compounds
- Stability testing and compatibility studies
- Waste management consultation
Industry Certifications
Our manufacturing facilities maintain the following certifications:
| ISO 9001:2015 | Quality Management System |
| ISO 14001:2015 | Environmental Management System |
| OHSAS 18001 | Occupational Health and Safety |
| cGMP | For pharmaceutical-grade production |
| Responsible Care® | Chemical industry initiative for EHS performance |